Function ◎ 32 wireless zones and 8wired zones. ◎ No limited on the quantity of wireless siren enroll to the panel ◎ can enroll 8 extra remote controller,enable ajust the volume of voice indication. ◎ detector loss inspection function, communication inspection function , tel-line coneect inspection. ◎A/C off, low battery alarm function ◎ 2 CMS phone #, 4 follow me private phone ◎ 15 seconds for user to record personalization voice alarm ◎No limited on the quantity of wireless siren enroll to the panel.
Ref.: FC-7216
◎Support two-way communication, enable work with 8 two-way wired keypad or 8 dual-way wireless keypad, 8 two-way intelligent remote Control.
◎support GSM and TCP/IP protocol,network alarm settings.
◎Brand-new 16 bits high speed MCU, with voice prompt operation.
◎Contact ID communication protocol, MEIAN-II BUS protocol.
◎Built-in electronic clock supporting 4 groups timing arm/disarm, 2 groups timing alarm clock.
◎16-channels remote control program.
◎Can connect with alarm linkage output.
◎Subsection record, partition arm , auto listening-in spot.
◎AC fault or wireless/wired detectors trouble reporting function.
◎Can set self-checking time auto reporting control panel.
Ref.: FC-7240
FUNCTION
◎All English prompt, rolling menu programming. ◎ 8 wired zones,32 BUS zones. ◎ 4 subsystems,two-way communication. ◎support GSM and TCP/IP protocol,network alarm settings. ◎extend GPRS wireless communication module, support GPRS data transmission. ◎Built-in video module,view the video output images online. ◎32 wireless appliance switch, electrical switch timing control. ◎4 CMS number(Contact ID protocol), 4 private voice number, 2 group free arm/disarm number. ◎Muti-Code Non-repeat holographic code. ◎Build-in songs doorbell and sound siren. ◎Remote control by telephone,10s address recording, arm/disarm timely and freely. ◎Telephone line cut alarm Reminder windows and doors is not closed.
Ref.: FC-7308
◎Central units core of powerful RISC microprocessor; ◎The electrical features include an EEPROM memory for the programmed configuration, system/partitions status and LOG buffer to be retained even after a total power loss; ◎User-friendly programming of the system parameters, from keypad or by PC ; ◎Up to 425 events with time and date stamp can be stored in a FIFO LOG buffer; ◎False alarm prevention” features: intellizones, automatic zone shutdown, beeps on entry and exit delays. ◎High-speed Communication Format; ◎30 user codes (1-st being „master code”) and 1 installer programming code; ◎Keypad displayed alarm memory alarms occurred in the system since last arming; ◎Up to 4 keypads which can be simultaneously 4-wire coupled to one central unit; ◎Keypad protection using micro-switch tamper; ◎Individual zone LEDs from 1 to 10, indicating the alarm and faulted status; ◎Each zone accepts zone doubling and tamper recognition; ◎LEDs meaning on KP-106P keypad; ◎Individual Zone LEDs from 1 to 10, indicating the alarm and faulted status; ◎Status LEDs: SYSTEM, A & B ARMED, A & B READY, and BYPASS.
Ref.: FC-7340
◎Full touch screen glass board panel ◎Speech indication for all operation steps, English LCD screen, Easy to operate than before ◎All English prompt, rolling menu programming. ◎8 wired 32 wireless/BUS zone, ◎Support two-way communication,8 two-way remote controller ◎support GSM and TCP/IP protocol,network alarm settings。 ◎extend GPRS wireless communication module, support GPRS data transmission ◎Wireless/wired zone status real time monitoring. Wireless detector status real time monitoring ◎4 CMS number(Contact ID protocol), 4 private voice number, 2 group free arm/disarm number. ◎4 group timing arm/disarm setting. Remotely arm, disarm, listen-in function ◎Remote voice prompt operation.
Ref.: FC-7564*
1.GSM+GPRS+PSTN support contact ID(mobile +telephone communication) 2. 8 wired zones+24 wireless zones+32 bus zones 3.10 keypads+16 wireless remote controller 4. 2 CMS phone #,1 account number 5. 8 wireless siren,32 channels electronic appliance control 6.4 follow me phone # 7. 128 event log
Ref.: FC-7664
FUNCTION ◎Support two-way communication, enable work with 8 two-way wired keypad or 8 dual-way wireless keypad, 8 two-way intelligent remote Control. ◎support GSM and TCP/IP protocol,network alarm settings. ◎Brand-new 16 bits high speed MCU, with voice prompt operation. ◎16 wired + 24 wireless+24 Bus. ◎2 CMS telephone number, 1 remote programming telephone number, 8 private alarm telephone number. ◎Contact ID communication protocol, MEIAN-II BUS protocol. ◎Built-in electronic clock supporting 4 groups timing arm/disarm, 2 groups timing alarm clock. ◎16-channels remote control program. ◎Can connect with alarm linkage output. ◎Subsection record, partition arm , auto listening-in spot. ◎AC fault or wireless/wired detectors trouble reporting function. ◎Can set self-checking time auto reporting control panel.
Ref.: FC-7668
Function
◎ Chinese&English operation menu and voice prompt.
◎8 tamper-checking wired zone,32 wireless zone,128 BUS zone(with tamper-checking single zone module)
◎ 8 wired zones,24wireless zones,32 BUS zones. ◎All English prompt, rolling menu programming. ◎Support two-way communication,8 two-way remote controller, 8 programmable access keypads. ◎support GSM and TCP/IP protocol,network alarm settings. ◎extend GPRS wireless communication module, support GPRS data transmission. ◎ extend programmable Relay modules, Serial port module. ◎ 8 private telephone number with voice indication. ◎Remote voice prompt operation. ◎Built-in electronic clock, can achieve 4 groups timing arm/disarm everyday, 2 groups timing alarm clock. ◎Status report to CMS of AC cut/wired or wireless sensor fault. ◎Self check status report to the panel. ◎ 512 event logs.
Ref.: PEGASUS(ST-IV)
FUNCTION ◎ Dual Serial Ports,access to wired and wireless keyboard. ◎ Support two-way communication, enable work with 8 dual-way wried keypad, 8 dual-way wireless keypad, 8 dual-way remote. ◎ support GSM protocol,network alarm settings. ◎ With 32 wireless zones, 8 wired zones. ◎ dopt bran new 16 bit MCU. ◎ Built-in video module,can view video o utput on line.
Ref.: ST-II
FUNCTION
. Voice indication for operation Easy to operate than before.
2. Dual Serial Ports,access to wired and wireless keyboard.
3. Support two-way communication, enable work with 8 dual-way wried keypad, 8 dual-way wireless keypad, 8 dual-way remote.
4. support GSM protocol,network alarm settings.
5. With 32 wireless zones, 8 wired zones.
6. dopt bran new 16 bit MCU.
7.Built-in video module,can view video o utput on line. Basic Function.
Ref.: ST-IIIB
Function ◎8 wired zone,32 wireless zones ◎8 electronic appliance control. Enbale switch on/off, inquiry electronic appliance on/off status via phone remotely ◎enable code 8 wireless remote, enable ajust the volume of voice indication. ◎15 seconds for user to record personalization voice alarm .No limited on the quantity of wireless siren enroll to the panel ◎ Auto testing user online status, 120 events records system. ◎ detector loss inspection function, communication inspection function , tel-line coneect inspection. ◎ A/C off, low battery alarm function ◎ 2 CMS phone #, 4 follow me private phone. ◎Auto testing user online status, 120 events records system.
Ref.: ST-IVBWhole
Basic functions: ◎ Full touch screen glass board panel ◎ Speech indication for all operation steps, English LCD screen, Easy to operate than before ◎ 8 wired 32 wireless zone, 32 BUS zone,210 zone total ◎ 4 subsystem, bidirectional wireless communication ◎ Build-in GSM, TCP/IP module ◎ Build-in GPRS wireless communication module, support GPRS data transmission. ◎ 32 electric appliance control, electric appliance switch timely control ◎ Muti-Code Non-repeat holographic code ◎ Build-in songs doorbell and sound siren ◎ Remote control by telephone,10s address recording, arm/disarm timely and freely.
Ref.: ST-V
New Function ◎ Dual Serial Ports,access to wired and wireless keyboard. ◎ Support two-way communication, enable work with 8 dual-way wried keypad, 8 dual-way wireless keypad, 8 dual-way remote. ◎ support GSM and TCP/IP protocol,network alarm settings. ◎ With 32 wireless zones, 8 wired zones. ◎ dopt bran new 16 bit MCU. ◎ Built-in video module,can view video output on line. Basic Function ◎ Voice indication for operation, LCD display,Easy to operate than before. ◎ 8 wired 32 wireless zone, 32 BUS zone,210 zone total ◎ 4 subsystem, bidirectional wireless communication